FR-A840-2.2K-7.5K Biến Tần Mitsubishi 2.2K-7.5K, 3 Pha 380 VAC: FR-A840
- FR-A840-83(2.2K)
- FR-A840-126(3.7K)
- FR-A840-170(5.5K)
- FR-A840-250(7.5K)
Model FR-A840-[ ](-E)(GF) | 83 | 126 | 170 | 250 | |||
2.2K | 3.7K | 5.5K | 7.5K | ||||
Applicable motor capacity (kW) *1 | SLD | 3.7 | 5.5 | 7.5 | 11 | ||
LD | 3.7 | 5.5 | 7.5 | 11 | |||
ND (initial setting) | 2.2 | 3.7 | 5.5 | 7.5 | |||
HD | 1.5 | 2.2 | 3.7 | 5.5 | |||
Output | Rated capacity (kVA) *3 | SLD | 6.3 | 10 | 13 | 19 | |
LD | 5.8 | 8.8 | 12 | 18 | |||
ND (initial setting) | 4.6 | 6.9 | 9.1 | 13 | |||
HD | 3 | 4.6 | 6.9 | 9.1 | |||
Rated current (A) |
SLD | 8.3 | 12.6 | 17 | 25 | ||
LD | 7.6 | 11.5 | 16 | 23 | |||
ND (initial setting) | 6 | 9 | 12 | 17 | |||
HD | 4 | 6 | 9 | 12 | |||
Overload current rating *4 |
SLD | 110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C | |||||
LD | 120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C | ||||||
ND (initial setting) | 150% 60 s, 200% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C | ||||||
HD | 200% 60 s, 250% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C | ||||||
Rated voltage *5 | Three-phase 380 to 500 V | ||||||
Regenerative braking | Brake transistor | Built-in | |||||
Maximum brake torque *7 | 100% torque/2%ED *6 | ||||||
FR-ABR (when the option is used) |
100% torque/10%ED | ||||||
Power supply | Rated input AC voltage/frequency |
Three-phase 380 to 500 V 50 Hz/60 Hz *11 | |||||
Permissible AC voltage fluctuation | 323 to 550 V 50 Hz/60 Hz | ||||||
Permissible frequency fluctuation | ±5% | ||||||
Rated input current (A) *8 | Without DC reactor |
SLD | 10.9 | 16.4 | 22.5 | 31.7 | |
LD | 10.1 | 15.1 | 22.3 | 31 | |||
ND (initial setting) | 8.3 | 12.3 | 17.4 | 22.5 | |||
HD | 6.2 | 8.3 | 12.3 | 17.4 | |||
With DC reactor |
SLD | 8.3 | 12.6 | 17 | 25 | ||
LD | 7.6 | 11.5 | 16 | 23 | |||
ND (initial setting) | 6 | 9 | 12 | 17 | |||
HD | 4 | 6 | 9 | 12 | |||
Power supply capacity (kVA) *9 |
Without DC reactor |
SLD | 8.3 | 12 | 17 | 24 | |
LD | 7.7 | 12 | 17 | 24 | |||
ND (initial setting) | 6.3 | 9.4 | 13 | 17 | |||
HD | 4.7 | 6.3 | 9.4 | 13 | |||
With DC reactor |
SLD | 6.3 | 10 | 13 | 19 | ||
LD | 5.8 | 8.8 | 12 | 18 | |||
ND (initial setting) | 4.6 | 6.9 | 9.1 | 13 | |||
HD | 3 | 4.6 | 6.9 | 9.1 | |||
Protective structure (IEC 60529) *10 | Enclose type (IP20) | ||||||
Cooling system | Forced air cooling | ||||||
Approx. mass (kg) | 3.3 | 3.3 | 6.7 | 6.7 |
=======================